Cool roofs for passive cooling: performance in different climates and for different insulation levels in ItalyCostanzo, V., Evola, G. and Marletta, L. (2013) Cool roofs for passive cooling: performance in different climates and for different insulation levels in Italy. Advances in Building Energy Research, 7 (2). pp. 155-169. ISSN 1751-2549 Full text not archived in this repository. It is advisable to refer to the publisher's version if you intend to cite from this work. See Guidance on citing. To link to this item DOI: 10.1080/17512549.2013.865556 Abstract/SummaryRoofs are severely hit by solar radiation in summer; hence the use of cool materials on the finishing layer provides a significant reduction in the heat flow entering the building, with sensible attenuation in the building cooling load. In this paper, a case study is presented, based on the dynamic simulation of an existing office building in Catania (southern Italy). Here, a part of the roof has been recently treated with a commercial cool paint, with the aim of improving thermal comfort in summer. Hence, the simulations represent a preliminary study that will allow assessing the expected effectiveness of the intervention. More in detail, the results of the simulations will be discussed in terms of both thermal comfort and energy savings, through the evaluation of parameters such as the roof surface temperature, the operative temperature and the cooling load for both conditions, i.e. with and without the cool paint. The paper also discusses the potential increase in the energy needs for winter heating, and looks at the overall annual balance in terms of primary energy; this is made by considering different climatic conditions and envelope characteristics. These aspects are usually not well highlighted in the current scientific literature.
Altmetric Deposit Details University Staff: Request a correction | Centaur Editors: Update this record |