Accessibility navigation


Accuracy and spatial properties of distributed magnetic source imaging techniques in the investigation of focal epilepsy patients

Pellegrino, G., Hedrich, T., Porras-Bettancourt, M., Lina, J.-M., Aydin, Ü. ORCID: https://orcid.org/0000-0002-6327-7811, Hall, J., Grova, C. and Kobayashi, E. (2020) Accuracy and spatial properties of distributed magnetic source imaging techniques in the investigation of focal epilepsy patients. Human Brain Mapping, 41 (11). pp. 3019-3033. ISSN 1097-0193

[img] Text (Open Access) - Published Version
· Restricted to Repository staff only
· The Copyright of this document has not been checked yet. This may affect its availability.
· Available under License Creative Commons Attribution.

9MB

It is advisable to refer to the publisher's version if you intend to cite from this work. See Guidance on citing.

To link to this item DOI: 10.1002/hbm.24994

Abstract/Summary

Source localization of interictal epileptiform discharges (IEDs) is clinically useful in the presurgical workup of epilepsy patients. We aimed to compare the performance of four different distributed magnetic source imaging (dMSI) approaches: Minimum norm estimate (MNE), dynamic statistical parametric mapping (dSPM), standardized low-resolution electromagnetic tomography (sLORETA), and coherent maximum entropy on the mean (cMEM). We also evaluated whether a simple average of maps obtained from multiple inverse solutions (Ave) can improve localization accuracy. We analyzed dMSI of 206 IEDs derived from magnetoencephalography recordings in 28 focal epilepsy patients who had a well-defined focus determined through intracranial EEG (iEEG), epileptogenic MRI lesions or surgical resection. dMSI accuracy and spatial properties were quantitatively estimated as: (a) distance from the epilepsy focus, (b) reproducibility, (c) spatial dispersion (SD), (d) map extension, and (e) effect of thresholding on map properties. Clinical performance was excellent for all methods (median distance from the focus MNE = 2.4 mm; sLORETA = 3.5 mm; cMEM = 3.5 mm; dSPM = 6.8 mm, Ave = 0 mm). Ave showed the lowest distance between the map maximum and epilepsy focus (Dmin lower than cMEM, MNE, and dSPM, p = .021, p = .008, p < .001, respectively). cMEM showed the best spatial features, with lowest SD outside the focus (SD lower than all other methods, p < .001 consistently) and high contrast between the generator and surrounding regions. The average map Ave provided the best localization accuracy, whereas cMEM exhibited the lowest amount of spurious distant activity. dMSI techniques have the potential to significantly improve identification of iEEG targets and to guide surgical planning, especially when multiple methods are combined.

Item Type:Article
Refereed:Yes
Divisions:No Reading authors. Back catalogue items
ID Code:111224
Uncontrolled Keywords:Adolescent, Adult, Brain Mapping, Cerebral Cortex/physiopathology, Electrocorticography/methods, Electroencephalography/methods, Epilepsies, Partial/diagnosis, Female, Humans, Magnetoencephalography/methods, Male, Young Adult
Publisher:Wiley

University Staff: Request a correction | Centaur Editors: Update this record

Page navigation