Stressing the passive behavior of a Passivhaus: an evidence-based scenario analysis for a Mediterranean case study

Costanzo, V., Fabbri, K. and Piraccini, S. (2018) Stressing the passive behavior of a Passivhaus: an evidence-based scenario analysis for a Mediterranean case study. Building and Environment, 142. pp. 265-277. ISSN 0360-1323

[img]
Preview
Text - Accepted Version
· Available under License Creative Commons Attribution Non-commercial No Derivatives.
· Please see our End User Agreement before downloading.

2MB

It is advisable to refer to the publisher's version if you intend to cite from this work. See Guidance on citing.

To link to this item DOI: 10.1016/j.buildenv.2018.06.035

Abstract/Summary

This paper first reports the outcomes of a one-year measurement campaign of a passive house built in the Mediterranean climate of Cesena (Italy) in terms of thermal comfort parameters temperature and relative humidity and Indoor Environmental Quality (IEQ) parameter CO2 concentrations. The design carried out with the help of the steady state Passive House Planning Package (PHPP) was able to guarantee good comfort conditions during the heating period, but on the other hand, overheating occurrences during the cooling season have been recorded for almost 50% time according to EN 15251 Standard. Further analyses conducted with the help of dynamic simulations in EnergyPlus allowed identifying the insulation levels and ventilation mode as the key design factors to change in order to reduce overheating to less than 20% of time while keeping a comfortable indoor environment in winter. The simplifications that can be made by reducing the insulation material thickness (up to a third of the original value) on the roof and on the walls, replacing triple-glazed windows with double-glazed windows and implementing a hybrid ventilation strategy instead of using Mechanical Ventilation with Heat Recovery (MVHR) alone could also lead to economic savings. These savings, due to both lower construction costs and operational energy savings, amount to 8755 euros in terms of Net Present Value (NPV) over 30 years' time. The Passivhaus Standard can still be regarded as a good reference for designing low-energy and comfortable houses in a Mediterranean climate if some simplifications are made according to detailed building performance simulations.

Item Type:Article
Refereed:Yes
Divisions:Science > School of the Built Environment
ID Code:77761
Publisher:Elsevier