A novel flow-guide device for uniform exhaust in a central air exhaust ventilation system

Tong, L., Gao, J., Luo, Z. ORCID: https://orcid.org/0000-0002-2082-3958, Wu, L., Zeng, L., Liu, G. and Wang, Y. (2019) A novel flow-guide device for uniform exhaust in a central air exhaust ventilation system. Building and Environment, 149. pp. 134-145. ISSN 0360-1323

[img]
Preview
Text - Accepted Version
· Available under License Creative Commons Attribution Non-commercial No Derivatives.
· Please see our End User Agreement before downloading.

3MB

It is advisable to refer to the publisher's version if you intend to cite from this work. See Guidance on citing.

To link to this item DOI: 10.1016/j.buildenv.2018.12.007

Abstract/Summary

Exhaust ventilation system with one central fan and multiple terminals has been widely used for the heat and contaminant removal in building environment. Conventional design without pressure balancing leads to uneven distribution of exhaust airflow rate among the multiple outlets. Existed balancing methods usually uses dampers (constant-air-volume valve or regulating valve), tapered duct, or varied inlet area. However, these methods result in higher fan energy consumption, or complicated construction and on-site commissioning. In this paper, a flow-guide device was developed for adjusting the pressure distribution of duct branches. This new device is integrated with the interflow Tee-junction and does not need any commissioning or regulating. The resistance performance of the device responding to the structural parameter was derived using the CFD simulation and experiment. The negative direct resistance featured by the device was found to effectively benefit exhaust at the outlets farther away from the central fan. The ductwork hydraulic model based on the Bernoulli's law of airflow and the fitted resistance correlations were further proposed to fulfill the parametric design. Finally, full-scale test was carried out for a central exhaust system installed with the flow-guide devices referring to a factory workshop with heat and contaminant sources. Compared to the system without the devices, the total rate of the system increased by 25%. Discrepancy of exhaust rate decreased by 78% and uneven degree decreased by 82%, which well meets the engineering balancing requirement. Meanwhile, total resistance of the system reduced 23.8% owing to the negative loss the devices bring.

Item Type:Article
Refereed:No
Divisions:Interdisciplinary Research Centres (IDRCs) > Walker Institute
Science > School of the Built Environment > Urban Living group
Science > School of the Built Environment > Energy and Environmental Engineering group
ID Code:80997
Publisher:Elsevier

Downloads

Downloads per month over past year

University Staff: Request a correction | Centaur Editors: Update this record

Page navigation