Examination of methods to separate overlapping metabolites at 7T

[thumbnail of Open Access]
Preview
Text (Open Access)
- Published Version
· Available under License Creative Commons Attribution Non-commercial No Derivatives.
[thumbnail of Bell et al 2025 MRM.docx]
Text
- Accepted Version
· Restricted to Repository staff only

Please see our End User Agreement.

It is advisable to refer to the publisher's version if you intend to cite from this work. See Guidance on citing.

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Bell, T. K. ORCID: https://orcid.org/0000-0002-9591-706X, Goerzen, D. ORCID: https://orcid.org/0000-0001-9645-3503, Near, J. ORCID: https://orcid.org/0000-0003-3516-936X and Harris, A. D. ORCID: https://orcid.org/0000-0003-4731-7075 (2024) Examination of methods to separate overlapping metabolites at 7T. Magnetic Resonance in Medicine, 93 (2). pp. 470-480. ISSN 0740-3194 doi: 10.1002/mrm.30293

Abstract/Summary

Purpose Neurochemicals of interest quantified by MRS are often composites of overlapping signals. At higher field strengths (i.e., 7T), there is better separation of these signals. As the availability of higher field strengths is increasing, it is important to re‐evaluate the separability of overlapping metabolite signals. Methods This study compares the ability of stimulated echo acquisition mode (STEAM‐8; TE = 8 ms), short‐TE semi‐LASER (sLASER‐34; TE = 34 ms), and long‐TE semi‐LASER (sLASER‐105; TE = 105 ms) acquisitions to separate the commonly acquired neurochemicals at 7T (Glx, consisting of glutamate and glutamine; total N‐acetyl aspartate, consisting of N‐acetyl aspartate and N‐acetylaspartylglutamate; total creatine, consisting of creatine and phosphocreatine; and total choline, consisting of choline, phosphocholine, and glycerophosphocholine). Results sLASER‐34 produced the lowest fit errors for most neurochemicals; however, STEAM‐8 had better within‐subject reproducibility and required fewer subjects to detect a change between groups. However, this is dependent on the neurochemical of interest. Conclusion We recommend short‐TE STEAM for separation of most standard neurochemicals at 7T over short‐TE or long‐TE sLASER.

Altmetric Badge

Item Type Article
URI https://centaur.reading.ac.uk/id/eprint/125526
Identification Number/DOI 10.1002/mrm.30293
Refereed Yes
Divisions No Reading authors. Back catalogue items
Life Sciences > School of Psychology and Clinical Language Sciences > Department of Psychology
Publisher Wiley
Download/View statistics View download statistics for this item

Downloads

Downloads per month over past year

University Staff: Request a correction | Centaur Editors: Update this record